Skip to Content To homepage

Brr 20/8452

Peltier-controlled cuvette holder with extended low temperature response for the Olis Computerized HP 8452 Diode Array
Product Overview

The Brr 20/8452 is a temperature-controlled cuvette holder for the range of +110 °C down to -55 °C. It is designed for use in the open sample compartment of your 8452 Diode Array System. Set and maintain precise sample temperatures and stir at a steady reproducible rate, while bathing the cuvette in a controlled gaseous environment. This product is provided with a windowed vest to enhance performance at low temperatures and minimize condensation that may form on the windows. Circulating water is used to remove heat from the Peltier heat exchanger. Control using the TC 1B Temperature Controller, included in the purchase price. For additional control and temperature monitoring, use Quantum Northwest’s computer control software, T-App, available for purchase.
Many experiments will benefit from the Brr 20/8452 alone. If you have greater needs, our partnership with OLIS, Inc. of Bogart, GA can enable you to assemble a new system. Let OLIS upcycle the HP 8452 to capabilities far beyond those it had when new. Retire ChemStation and upgrade to OLIS SpectralWorks. This Windows 7/10 program includes software for 2D and 3D analysis of kinetic and equilibrium data. Achieve the full potential of your HP 8452 with OLIS and Quantum Northwest. Contact us for more information.

Product Features

Rapid, precise Peltier temperature control -55 °C to +110 °C
Precise stepper-motor-driven magnetic stirring
Dry gas purge for work at low temperature
Insulated lid to improve temperature stability
Threaded inserts to mount windows or filters
Cuvette lifter for removal of cuvette
Probe input for sample temperature
Mounting base and post for the Cary 84542
NIST-traceable temperature calibration

  • Technical Specifications
    Number of cuvettes controlled
    1
    Typical use
    Absorbance
    Standard cuvette size (outside)
    12.5 mm x 12.5 mm
    Optical ports per cuvette
    2
    Optical port dimensions
    12 mm high x 10 mm wide
    Cuvette z-height
    15 mm
    Windowed vest available
    yes
    Factory set temperature range
    -55 °C to +110 °C
    Temperature range easily achievable
    -55 °C to +110 °C
    Temperature precision
    ±0.02 °C
    Thermistor probes accepted
    Probe/10k-Brr
    Magnetic stirring motor type
    Stepper
    Magnetic stirring speed range
    1-2500 rpm
    Default stirring speed
    1200 rpm
    Stirring speed best performance
    60-1800 rpm
  • Basic Package

    Brr 20 – Temperature-controlled cuvette holder
    TC 1B – Temperature Controller
    Mounting plate and fasteners
    NIST-traceable calibration and performance data
    Magnetic stir bar, tubing for water and dry gas, and cables

  • Accessories