Skip to Content To homepage

Luma 40/920

Peltier-based temperature-controlled cuvette holder for the Edinburgh Instruments FL920 and OB920 Spectrometers
Product Overview

Use the Luma 40/920 as a cuvette holder upgrade to provide temperature control for the now discontinued FLS920 Fluorescence Spectrometer of Edinburgh Instruments. Use the Luma 409/920 for normal temperature ranges of -15 °C to +105 °C. Add a Windowed Jacket, purge with dry gas and run the temperature down to at least -40 °C. Purchase the extended temperature option and extend the range up to +150 °C. Fluorescence is sensitive to temperature and reliable measurements require the precise temperature control of the Luma 40/920. The Luma 40/920 may be controlled using the menu button on the front of the TC 1/Single controller or through program T-App available from Quantum Northwest. Fully integrated control through the Spectrometer is available from Edinburgh Instruments.

Product Features

Four optical ports
Rapid, precise temperature control
Optional extended temperature range
Windowed jacket available for temperature extremes
Variable speed magnetic stirring
Dry gas purge for work at low temperature
Includes base and filter holders
Probe input for sample temperature
NIST-traceable temperature calibration
Fully integrated software control

  • Technical Specifications
    Number of cuvettes controlled
    1
    Typical use
    Fluorescence
    Standard cuvette size (outside)
    12.5 mm x 12.5 mm
    Optical ports per cuvette
    4
    Optical port dimensions
    12 mm high x 10 mm wide
    Built-in optical slit holders
    4 per cuvette
    Cuvette z-height
    8.5 or 15 mm for most models
    Windowed jacket available
    2, 3 or 4 windows
    Normal factory set temperature range
    -40 °C to +105 °C
    Temperature range easily achievable
    -15 °C to +105 °C
    Range with special techniques
    -40 °C to +105 °C
    Extended factory set temperature range
    -55 °C to +150 °C
    Extended temperature range achievable
    -50 °C to +150 °C
    Accuracy greater range
    Better than ±0.3 ⁰C from ‐20 ⁰C to +110 ⁰C
    Temperature reproducibility
    Better than ±0.07 °C
    Thermistor probes accepted
    Series 400 or Series 500
    Magnetic stirring motor type
    Stepper
    Magnetic stirring speed range
    1-2500 rpm
    Default stirring speed
    1200 rpm
    Stirring speed best performance
    60-1800 rpm
  • Basic Package

    Luma 40 – Temperature-controlled cuvette holder (standard z-height = 8.5 mm)
    TC 1/Single – Temperature Controller
    Base for mounting in the spectrometer
    BATH 10 – Circulator
    NIST-traceable calibration and performance data
    Accessories – Magnetic stir bar, tubing, cables, optical slits and opaque cap

  • Accessories
Other Products to Consider
Back to top