Skip to Content To homepage

Luma 40/EVO

Temperature-controlled cuvette holder with four optical ports for the Evolution 300 and 600 Spectrophotometers
Product Overview

The Luma 40/EVO has four optical ports around the cuvette. Use it for absorbance measurements when your experiment requires access at 90 degrees for photochemical activation. Purchase the extended temperature option and run the Luma 40/EVO up to 150 °C for non-aqueous samples. Add a Windowed Jacket, purge with dry gas and run the temperature down to at least -40 °C. The Luma 40 is also ideal for work in the biological range of 0 °C to 110 °C. Use it to observe absorbance spectra at precisely maintained temperatures, or for temperature ramping, to observe how absorbance changes with temperature. Operate the TC 1/Single Temperature Controller using the menu button or control via optional program T-App.

Product Features

Four optical ports
Rapid, precise temperature control
Optional extended temperature range
Windowed jacket available for temperature extremes
Variable speed magnetic stirring
Dry gas purge for work at low temperature
Base and post for mounting in spectrometer
Probe input for sample temperature
NIST-traceable temperature calibration
Default stirring speed: 1200 rpm
Stirring speed best performance: 900-1800 rpm

  • Technical Specifications
    Number of cuvettes controlled
    1
    Typical use
    Fluorescence
    Standard cuvette size (outside)
    12.5 mm x 12.5 mm
    Optical ports per cuvette
    4
    Optical port dimensions
    12 mm high x 10 mm wide
    Built-in optical slit holders
    4 per cuvette
    Cuvette z-height
    8.5 or 15 mm for most models
    Windowed jacket available
    2, 3 or 4 windows
    Normal factory set temperature range
    -40 °C to +105 °C
    Temperature range easily achievable
    -15 °C to +105 °C
    Range with special techniques
    -40 °C to +105 °C
    Extended factory set temperature range
    -55 °C to +150 °C
    Extended temperature range achievable
    -50 °C to +150 °C
    Accuracy greater range
    Better than ±0.3 ⁰C from ‐20 ⁰C to +110 ⁰C
    Temperature reproducibility
    Better than ±0.07 °C
    Thermistor probes accepted
    Series 400 or Series 500
    Magnetic stirring motor type
    Stepper
    Magnetic stirring speed range
    1-2500 rpm
    Default stirring speed
    1200 rpm
    Stirring speed best performance
    60-1800 rpm
  • Basic Package

    Luma 40 – Temperature-controlled cuvette holder (standard z-height = 15 mm)
    TC 1/Single – Temperature Controller
    Base plate
    Bath 10 – Circulator
    NIST-traceable calibration and performance data
    Accessories – Magnetic stir bar, tubing, cables, optical slits and opaque cap

  • Accessories