Discover the t2x2 Sport: a temperature-controlled cuvette holder designed for absorbance spectroscopy. It offers precise, independent control from 15 °C to 110 °C for both the sample and reference cuvettes, along with built-in stirring. With its compact, cost-effective design, it’s ideal for budget-conscious labs.
AbsorbanceThe t2x2 Sport is a compact, cost-effective dual cuvette holder designed for precise, independent temperature control of both sample and reference cuvettes. Mounted on a base plate that precisely positions each cuvette in the correct beam path, it requires no alignment. With optical ports on each side of both cuvette holders, it supports absorbance measurements utilizing a 180° beam path. Both holders are designed to accommodate standard 10 mm square cuvettes, with options for slimmer cuvettes using Quantum Northwest’s thermal conductive adapters.
Operating from -15 °C to 110 °C, the t2x2 Sport ensures exceptional thermal stability using thermoelectric temperature control and a water-cooled heat exchanger. Both cuvette holders can maintain the same temperature or operate independently at different temperatures. Inert dry gas flow helps maintain optical clarity at lower temperatures by reducing condensation. Integrated stirring provides steady, reproducible mixing for both cuvettes. Like all Quantum Northwest sample holders, the t2x2 Sport provides unsurpassed temperature control, ensuring stable hold temperatures within a fraction of a degree.
Control is straightforward using the TC-1 Temperature Controller, included with purchase. Users can set sample and reference temperatures, stirring speeds, and ramp rates via the TC-1’s front panel or through T-App, Quantum Northwest’s optional control software, which provides features like real-time plotting, scripting, and direct sample temperature measurement when paired with the optional Probe/10K sensor. Even without T-App, the TC-1 display provides a direct readout of the sample temperature when using the Probe/10K.
The t2x2 integrates with a wide range of spectrophotometers. Browse our available models to find one compatible with your instrument. If an existing model does not fit your instrument or only partially meets your application requirements, contact us to explore customization options.
Combining reliability, flexibility, affordability, and adding an additional holder for the reference cuvette the t2x2 Sport is a trusted solution for steady-state and temperature ramping experiments in spectroscopy laboratories of all sizes.
|
Number of samples controlled | 2 Cuvette |
|
Designed usage | Absorbance |
|
Sample container size | Standard cuvette 12.5 mm x 12.5 mm (outside) |
|
Optical ports per cuvette | 2 |
|
Optical port dimensions | 12 mm high x 10 mm wide |
|
Built-in optical slit holders | No |
|
Cuvette z-height | 8.5 mm or 15 mm |
|
Windowed jacket or vest available | No |
|
Method of heat dissipation | Water Circulation |
|
Programable temperature range |
-40 to 110°C |
|
*Temperature range |
-15 to 110°C |
|
Extended temperature options available | No |
|
**(Extended) Programable temperature range | Not Applicable |
|
**(Extended) Temperature range | Not Applicable |
|
Thermistor probes accepted | Probe/10k |
|
Magnetic stirring motor type | Stepper |
|
Default stirring speed | 1200 rpm |
|
Stirring speed range | 1-2500 rpm |
|
Stirring speed range (Best performance) | 60-1800 rpm |
*The holder's temperature performance depends on the operating environment and setup conditions, which must support proper heat dissipation and condensation reduction. While the listed temperatures are consistently achieved during testing, they are not guaranteed in all environments or setups. Meeting the ideal setup conditions outlined in the product's manual is necessary to achieve specific temperature stages.
**The extended range applies only when all corresponding High or Low customization options are implemented. The higher limit is extended by the High Limit package option, and the lower limit is extended by the Low Limit package option.
Included
Optional
Magnetic stir bar (qty 2)

NIST-traceable calibration and performance data

Tubing for dry gas and water circulation

Equipment Cables

Water Circulator System (BATH 10)

TC-1 Dual Temperature Controller

CAL/Dual

ADAPT/Abs/5mm

ADAPT/Abs/2mm

ADAPT/Abs/1mm

ADAPT/Abs/0.5mm

Probe/10k

T-App Software

Magnetic stir bar (qty 2)
Included
NIST-traceable calibration and performance data
Included
Tubing for dry gas and water circulation
Included
Equipment Cables
Included
Water Circulator System (BATH 10)
Included
TC-1 Dual Temperature Controller
Included
CAL/Dual
Optional
ADAPT/Abs/5mm
Optional
ADAPT/Abs/2mm
Optional
ADAPT/Abs/1mm
Optional
ADAPT/Abs/0.5mm
Optional
Probe/10k
Optional
T-App Software
Optional
Manufacture
Model
PG Instruments
t2x2 Sport/T92
Shimadzu
t2x2 Sport/Shimadzu
Hitachi
t2x2 Sport/Hitachi
Thermo
t2x2 Sport/EVO
Dynamica
t2x2 Sport/Dynamica
Edinburgh Analytical
t2x2 Sport/DB30
Agilent
t2x2 Sport/Cary4000-6000
Agilent
t2x2 Sport/Cary100-300
Perkin Elmer
t2x2 Sport/PE1050
More information for a custom approach with this product
Other products to consider
Turret 6
Absorbance, Circular Dichroism, FluorescenceRotary six- position temperature control cuvette holder.

Turret 4
Absorbance, FluorescenceRotary four-position temperature control cuvette holder.

t2 Sport
AbsorbanceCompact temperature control cuvette holder for absorbance.