qChanger 6
Discover the qChanger 6: a temperature-controlled cuvette holder designed for absorbance and fluorescence spectroscopy. It delivers precise temperature control from -15°C to 110°C, with built-in stirring for six cuvettes simultaneously. Ideal for laboratories that require rapid, parallel testing under uniform temperature conditions.
AbsorbanceThe qChanger 6 is a six-position, rapid-sliding, temperature-controlled cuvette holder designed for absorbance measurements. Each cuvette position features two optical ports, allowing 180° beam paths for precise optical alignment. The sliding assembly enables smooth transitions between cuvettes mid-experiment while ensuring consistent temperature across all six cells. Integrated stirring provides uniform mixing when required.
Operating from -15 °C to 110 °C, the qChanger 6 delivers exceptional thermal stability using thermoelectric temperature control and a water-cooled heat exchanger. To prevent condensation and maintain optical clarity at lower temperatures, inert dry gas flow is recommended. Failure to use gas at these temperatures may result in condensation, affecting measurements and potentially damaging internal components. Like all Quantum Northwest sample holders, the qChanger 6 provides unsurpassed temperature control, ensuring stable hold temperatures within a fraction of a degree.
Control is straightforward with the TC-1 Temperature Controller, included with purchase. Users can set temperatures, stirring speeds, and ramp rates via the TC-1’s front panel or through T-App, Quantum Northwest’s optional control software. T-App provides features such as real-time plotting, scripting, and direct sample temperature measurement when paired with the Probe/10K sensor. Even without T-App, the TC-1 display provides a direct readout of the sample temperature when using the Probe/10K.
The qChanger 6 integrates with a wide range of spectrophotometers. The standard model mounts easily to both imperial and metric optical breadboards, with additional models available for specific instruments. Browse our available models to find one compatible with your setup. If an existing model doesn’t fit your instrument or only partially meets your application requirements, contact us to explore customization options.
With its rapid cuvette switching, and precise temperature control, the qChanger 6 is ideal for high-throughput absorbance studies and experiments requiring efficient sample transitions. Its seamless integration with spectrophotometers and robust thermal stability make it a reliable choice for demanding laboratory applications.
|
Number of samples controlled 255_4c1b94-93> | 6 Cuvettes 255_16d9ba-2c> |
|
Designed usage 255_0db57c-07> | Absorbance 255_2d87c6-7e> |
|
Sample container size 255_c88322-48> | Standard cuvette 12.5 mm x 12.5 mm (outside) 255_5602b2-ba> |
|
Optical ports per cuvette 255_0c07bf-d5> | 2 255_59a04c-c7> |
|
Optical port dimensions 255_fbe058-01> | 10 mm high x 10 mm wide 255_f673f9-7e> |
|
Built-in optical slit holders 255_9d0e0e-24> | No 255_776ed1-9b> |
|
Cuvette z-height 255_b41fda-22> | 15mm 255_e16e51-f1> |
|
Windowed jacket or vest available 255_a3aace-fd> | No 255_1c77c7-eb> |
|
Method of heat dissipation 255_b33bda-2a> | Water Circulation 255_55f657-26> |
|
Programable temperature range 255_661bd9-e1> |
-40 to 110°C 255_9adf2e-83> |
|
*Temperature range 255_da25eb-3d> |
-15 to 110°C 255_8dde01-d3> |
|
Extended temperature options available 255_a72f39-77> | No 255_1d709a-a1> |
|
**(Extended) Programable temperature range 255_54d5b7-ee> | Not Applicable 255_7e3636-47> |
|
**(Extended) Temperature range 255_281eff-3c> | Not Applicable 255_d329ef-b5> |
|
Thermistor probes accepted 255_96c2e8-e1> | Probe/10k 255_3eb4a9-e2> |
|
Magnetic stirring motor type 255_85bc34-10> | Stepper 255_8d6f08-18> |
|
Default stirring speed 255_17a3b9-d6> | 1200 rpm 255_bd35ee-28> |
|
Stirring speed range 255_cdeba6-de> | 1-2500 rpm 255_36dad5-c3> |
|
Stirring speed range (Best performance) 255_8e1c2e-ba> | 60-1800 rpm 255_a94614-a4> |
*The holder's temperature performance depends on the operating environment and setup conditions, which must support proper heat dissipation and condensation reduction. While the listed temperatures are consistently achieved during testing, they are not guaranteed in all environments or setups. Meeting the ideal setup conditions outlined in the product's manual is necessary to achieve specific temperature stages.
**The extended range applies only when all corresponding High or Low customization options are implemented. The higher limit is extended by the High Limit package option, and the lower limit is extended by the Low Limit package option.
Included
Optional
NIST-traceable calibration and performance data

Tubing for dry gas and water circulation

Equipment Cables

TC-1 Temperature Controller

Water Circulator System (BATH 10)

Magnetic stir bar (qty 6)

CAL/Single

ADAPT/Abs/5mm

ADAPT/Abs/2mm

ADAPT/Abs/1mm

ADAPT/Abs/0.5mm

Probe/10k

T-App Software

NIST-traceable calibration and performance data
Included
Tubing for dry gas and water circulation
Included
Equipment Cables
Included
TC-1 Temperature Controller
Included
Water Circulator System (BATH 10)
Included
Magnetic stir bar (qty 6)
Included
CAL/Single
Optional
ADAPT/Abs/5mm
Optional
ADAPT/Abs/2mm
Optional
ADAPT/Abs/1mm
Optional
ADAPT/Abs/0.5mm
Optional
Probe/10k
Optional
T-App Software
Optional
Manufacture
Model
Shimadzu
qCHANGER 6/Shimadzu
Perkin Elmer
qCHANGER 6/PE365
Hitachi
qCHANGER 6/Hitachi
Agilent
qCHANGER 6/Cary50-60
Agilent
qCHANGER 6/Cary4000-6000
Agilent
qCHANGER 6/Cary100-300
Agilent (HP)
qCHANGER 6/8454
Agilent (HP)
qCHANGER 6/8453
Agilent (HP)
qCHANGER 6/8452
More information for a custom approach with this product
Other products to consider
Turret 6
Absorbance, Circular Dichroism, FluorescenceRotary six- position temperature control cuvette holder.

Turret 4
Absorbance, FluorescenceRotary four-position temperature control cuvette holder.

t2x2 Sport
AbsorbanceDual compact temperature control cuvette holder for absorbance.