qX2x2
Discover the qX2x2: a temperature-controlled cuvette holder designed for absorbance spectroscopy It offers precise, independent control from 0 °C to 110 °C for both the sample and reference cuvettes, along with built-in stirring. No water cooling is required, thanks to its integrated air-cooling fan. A great fit for space-conscious labs!
AbsorbanceThe qX2x2 is an air-cooled, dual cuvette holder designed for independent temperature control of both the sample and reference cuvettes in UV/Vis spectroscopy. Mounted on a base plate that precisely positions each cuvette in the correct beam path, it requires no alignment. With optical ports on each side of both cuvette holders, it supports absorbance measurements using a 180° beam path for each holder. It accommodates standard 10 mm square cuvettes, with options for slimmer cuvettes using Quantum Northwest’s thermal conductive adapters.
While both cuvette holders are air-cooled, the qX2x2 delivers performance comparable to water-cooled models, maintaining temperatures from 0 °C to 110 °C. It uses thermoelectric (Peltier) temperature control, with forced air efficiently dissipating heat, eliminating the need for a water bath.
The qX2x2 is designed with interchangeable cooling methods. While it ships as an air-cooled unit, it includes built-in water-cooling capabilities. By adding an insulated vest, attaching water inlet and outlet barbs, and connecting a water circulator—available at purchase or as a later upgrade—users can extend the cooling range down to approximately -35 °C. For applications requiring higher temperatures, a high-temperature option enables operation up to 150 °C, incorporating key internal modifications. This option must be selected at the time of purchase. Like all Quantum Northwest sample holders, the qX2x2 provides unsurpassed temperature control, ensuring stable hold temperatures within a fraction of a degree.
Control is straightforward using the TC-1 Temperature Controller, included with purchase. Users can set sample and reference temperatures, stirring speeds, and ramp rates via the TC-1’s front panel or through T-App, Quantum Northwest’s optional control software, which provides features like real-time plotting, scripting, and direct sample temperature measurement when paired with the optional Probe/10K sensor. Even without T-App, the TC-1 display provides a direct readout of the sample temperature when using the Probe/10K.
The qX2x2 integrates with a wide range of spectrophotometers. Browse our available models to find one compatible with your instrument. If an existing model does not fit your instrument or only partially meets your application requirements, contact us to explore customization options.
With efficient air cooling, extended temperature options, and dual independent temperature control, the qX2x2 is a versatile and powerful solution. Whether you need the convenience of air cooling or the extended range of water cooling, it can be adapted to your experimental needs, delivering stability, precision, and ease of use in a compact design.
|
Number of samples controlled 255_4c1b94-93> | 2 Cuvette 255_16d9ba-2c> |
|
Designed usage 255_0db57c-07> | Absorbance 255_2d87c6-7e> |
|
Sample container size 255_c88322-48> | Standard cuvette 12.5 mm x 12.5 mm (outside) 255_5602b2-ba> |
|
Optical ports per cuvette 255_0c07bf-d5> | 2 255_59a04c-c7> |
|
Optical port dimensions 255_fbe058-01> | 12 mm high x 10 mm wide 255_f673f9-7e> |
|
Built-in optical slit holders 255_9d0e0e-24> | 2 per cuvette 255_776ed1-9b> |
|
Cuvette z-height 255_b41fda-22> | 15 mm 255_e16e51-f1> |
|
Windowed jacket or vest available 255_a3aace-fd> | Yes, Optional Vest 255_1c77c7-eb> |
|
Method of heat dissipation 255_b33bda-2a> | Air Circulation (Optional Water Circulation) 255_55f657-26> |
|
Programable temperature range 255_661bd9-e1> |
-40 to 110°C 255_9adf2e-83> |
|
*Temperature range 255_da25eb-3d> |
0 to 110°C 255_8dde01-d3> |
|
Extended temperature options available 255_a72f39-77> | Yes 255_1d709a-a1> |
|
**(Extended) Programable temperature range 255_54d5b7-ee> | -40°C to 150°C 255_7e3636-47> |
|
**(Extended) Temperature range 255_281eff-3c> | -35°C to 150°C 255_d329ef-b5> |
|
Thermistor probes accepted 255_96c2e8-e1> | Probe/10k-qX 255_3eb4a9-e2> |
|
Magnetic stirring motor type 255_85bc34-10> | Stepper 255_8d6f08-18> |
|
Default stirring speed 255_17a3b9-d6> | 1200 rpm 255_bd35ee-28> |
|
Stirring speed range 255_cdeba6-de> | 1-2500 rpm 255_36dad5-c3> |
|
Stirring speed range (Best performance) 255_8e1c2e-ba> | 60-1800 rpm 255_a94614-a4> |
*The holder's temperature performance depends on the operating environment and setup conditions, which must support proper heat dissipation and condensation reduction. While the listed temperatures are consistently achieved during testing, they are not guaranteed in all environments or setups. Meeting the ideal setup conditions outlined in the product's manual is necessary to achieve specific temperature stages.
**The extended range applies only when all corresponding High or Low customization options are implemented. The higher limit is extended by the High Limit package option, and the lower limit is extended by the Low Limit package option.
Included
Optional
Tubing for dry gas

Magnetic stir bar (qty 2)

NIST-traceable calibration and performance data

Equipment Cables

TC-1 Dual Temperature Controller

Windowed Jacket

VBarb2

SpanSM1

FiltHoldSM1

RetRingSM1

WindowUV-1in

SLITS qX2

/E (Temp Package Option)

/L (Temp Package Option)

CAL/Dual

ADAPT/Abs/5mm

ADAPT/Abs/2mm

ADAPT/Abs/1mm

ADAPT/Abs/0.5mm

Probe/10k

T-App Software

Water Circulator System (BATH 10)

Probe/10k-qX

Tubing for dry gas
Included
Magnetic stir bar (qty 2)
Included
NIST-traceable calibration and performance data
Included
Equipment Cables
Included
TC-1 Dual Temperature Controller
Included
Windowed Jacket
Optional
VBarb2
Optional
SpanSM1
Optional
FiltHoldSM1
Optional
RetRingSM1
Optional
WindowUV-1in
Optional
SLITS qX2
Optional
/E (Temp Package Option)
Optional
/L (Temp Package Option)
Optional
CAL/Dual
Optional
ADAPT/Abs/5mm
Optional
ADAPT/Abs/2mm
Optional
ADAPT/Abs/1mm
Optional
ADAPT/Abs/0.5mm
Optional
Probe/10k
Optional
T-App Software
Optional
Water Circulator System (BATH 10)
Optional
Probe/10k-qX
Optional
Manufacture
Model
None
qX2x2/stnd
Shimadzu
qX2x2/Shimadzu
Perkin Elmer
qX2x2/PE365
Perkin Elmer
qX2x2/PE1050
Hitachi
qX2x2/Hitachi
Thermo
qX2x2/EVO
Dynamica
qX2x2/Dynamica
Agilent
qX2x2/Cary4000-6000
Agilent
qX2x2/Cary100-300
More information for a custom approach with this product
Other products to consider
Turret 6
Absorbance, Circular Dichroism, FluorescenceRotary six- position temperature control cuvette holder.

Turret 4
Absorbance, FluorescenceRotary four-position temperature control cuvette holder.

t2x2 Sport
AbsorbanceDual compact temperature control cuvette holder for absorbance.


